- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Join the global DP Community at the IMCA DP Conference in Amsterdam. 21 and 22 May. Book now
- Register your interest for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands.
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
Failure of personal isolation procedures: crane damaged when it was used inappropriately
What happened?
On a vessel in dry dock, a crane, which had been isolated for many days for work to be conducted by a third party, was used by crew unaware that the crane was out of use for maintenance. The crane was damaged as a result, leading to increased maintenance time and cost.
A “personal” isolation of the crane had been removed to allow a third party to function test the crane. A leak was found on the hydraulic system and work was being conducted to repair the issue. However, crew members not involved in the maintenance of the crane had a task to do which needed a crane, and they decided to try and operate the crane, resulting in damage.
What went wrong
Our members’ internal procedures for personal isolations were not adequately applied. It was noted by our member that this was not the first time this had occurred. The previous example had led to a crew member being exposed to 930Vdc.
A personal isolation is used when a single person conducts low risk work on a piece of equipment. They cannot be used by more than one person and cannot cross shifts. A personal isolation was used inappropriately in this case as it was applied over a number of days by more than one person working on the equipment.
Contributory factors
- The vessel was in dry dock and there was a weight limit of 5 tonnes on the crane. Operation of the crane was required to be communicated with the bridge to ensure vessel stability on the blocks;
- The scope of the crane maintenance work was non-routine and involved risks of pressurised hydraulics and movement of heavy machinery;
- A Permit to Work (PTW) should have been used but was not used:
- The task was not adequately risk assessed in accordance with the requirements for when a Permit to Work (PTW) was required;
- The lack of a PTW was a missed opportunity – had the PTW process been followed, the errors which led to the failure of personal isolation, would have been spotted.
- to follow the isolation procedure flowchart which would have captured the sanction to test control loop;
Personal isolation should only be used by persons directly involved in a low risk activity and within the duration of one shift. The isolation of the crane was not low risk and there was an injury potential from exposure to pressurised hydraulics. Also, third party personnel were not authorised to work using personal isolation at company worksites.
Safety Event
Published: 18 December 2023
Download: IMCA SF 29/23
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.