- Working in DP? Explore the recent changes announced by the Nautical Institute
- Check out our calendar and meet with us at upcoming industry events
- Registration open for IMCA Lifting & Rigging Seminar 2023
- Join us at our in-person Europe & Africa Regional Meeting in Rotterdam
- Iain Grainger announced as new CEO of IMCA
- Great speaker line up for our Safety Seminar in June 2023
Falls from step ladders
What happened?
A member reports two incidents in which persons fell off step ladders and were injured as a result.
Incident 1
While climbing back down a ladder from the 3rd step/rung, a crewman lost his footing and fell backwards landing on the deck grating, hitting his head and jarring his neck.
What went wrong?
- He did not check for safe securing of portable ladder;
- The uneven levelling of the deck was not considered prior to ladder use.


Incident 2
A forklift operator went up a step ladder to look at the top of container to ensure that there were no miscellaneous objects on top that could fall when the container was moved. As he came down again, while he was over a metre off the deck, the ladder became unstable and he fell off and broke his wrist on landing, and suffered contusions on the left leg and left side of the body. This was an LTI.


What went wrong?
- No risk assessment, permit to work or procedure was in place for the task or for the lifting of the container;
- There had been no check of the ladder before he started going up it – otherwise he might have noticed it was damaged;
- The broken ladders shouldn’t have been there at all: there was no routine inspections of ladders, and no quarantining of defective ladders;
- He was not wearing safety boots at the time of the incident;
- There was no training or awareness methods in place for the safe use of ladders.
Ladder safety
- Risk assessment and toolbox talk before working on ladders;
- Routine inspection of ladders, and procedures that identify the quarantining of damaged ladders;
- Inspect your ladder before you start work!
- Make sure you’re familiar with the hazards and risks before using a ladder;
- Position the ladder on a stable surface, where it won’t wobble.
Members may wish to refer to
Safety Event
Published: 10 November 2020
Download: IMCA SF 31/20
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.