Grease itself is a dropped object!
What happened?
During crane operations on an offshore vessel, quantities of grease fell from the crane block and landed on deck. The incident occurred in daylight, when a wellhead head was landed into its frame on the starboard side main deck. Riggers were stood by in a safe area ready to work on the load, when the client representative (who was present) heard a ‘splash’ sound and noted grease lying on the deck directly below the crane block.
This was a near miss; there were no injuries.
What went wrong? What were the causes?
The engine room crew greased the crane wire using the recommended greasing tool. The crew paid out the wire to 2800m, rinsed the wire and lubricated with the core lube pneumatic lubricator “Enviro X-433 EAL”. 2 x 19l pails were used.
The increased water pressure, combined with the increased wire temperature, caused the grease to come out of wire (could be mixture of original grease and the newly applied grease).
The crane manual does not provide a recommendation on the amount of grease to apply to the wire.
What actions were taken?
- Crane operations were stopped; the crane was racked and cleaned of excess grease;
- Crane pre-use checklist and toolbox talk (TBT) to include dropped grease hazard, both updated to include potential dropped objects and highlight potential for falling grease;
- Visual inspections on the accumulation points and removing excess grease.
What lessons were learned?
- Although classified as a liquid, crane grease is slightly viscous (between solid and liquid) and once a certain amount accumulates, it will drop to a lower level;
- Accumulation points are mainly the chandelier and sheave;
- Crane wire grease should be considered a dropped object;
- A ‘dropped object’ is any item that falls from its previous position.
Members may wish to refer to:
- Near-miss: Dropped object from crane
- Near-miss dropped object: Protector plate drops from crane [“These incidents serve to highlight the need to pay further careful attention to crane maintenance and to the clear risk of parts falling from the crane itself, in addition to managing the risk of objects falling from the load.”]
- IMCA DROPS videos:
- Technip DROPS
- Saipem DROPS – choice not chance
- DROPS [shared by Subsea 7]
Safety Event
Published: 17 September 2019
Download: IMCA SF 22/19
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.