High potential: dropped chain assembly
What happened
A chain assembly weighing 2.3kg fell 10m to deck, just glancing the helmet but potentially causing fatal injuries to a worker below. The incident occurred during lowering of a two-legged chain and a soft sling. The sling was flapping around due to the wind (9 m/s) and got caught on a railing. The hook flipped upside down and the master link of two legged chain was released from the hook. Consequently the chain fell 10 meters, grazing the helmet of the person working below. The person was shocked but otherwise unharmed.
![](https://imcaweb.blob.core.windows.net/wp-uploads/2023/08/chain-overview.png)
![](https://imcaweb.blob.core.windows.net/wp-uploads/2023/08/sling-and-hook.png)
What went wrong?
- The lifting technique was not correct: The fibre of the soft sling was caught in between the hook and latch preventing the safety mechanism from locking;
- People were in unsafe positions:
- The person with the remote control on the external platform did not have view of the load he was lowering;
- The injured person was working within the lifting area under the load when the chain and sling was being lowered.
- Insufficient communication: There was no communication between the two work areas when the chain assembly was being lowered.
Lessons learned
- Always check the lifting accessories are placed correctly in the hook;
- Ensure there are no people under the load – including the rigging itself which is also to be considered a load;
- Always keep an eye on the lift.
- Communicate lifts and inform team members on restricted areas;
- Does the crew have sufficient experience to perform the given tasks safely?
- Supervise less experienced colleagues;
- Follow the Life Saving Rules; wear PPE.
Members may wish to refer to:
Safety Event
Published: 3 August 2023
Download: IMCA SF 19/23
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.