High potential near miss: Crane part fell to deck
What happened
During a vessel transit during which the crane was unused in its boom rest, a crew member observed a piece of metal debris lying under the crane boom tip. It was discovered that one of the three Crane Whip Line Block Catcher Limit Switches (3.6kg) had fallen off and had fallen 6.5m to the deck. There were no injuries.
What went wrong
Our member noted the following:
- Inadequate design verification – the cross‐sectional area of the broken plate was not sufficient to bear the stress applied to the limit switch;
- The bolt spring was acting as a strong point and was creating unbalanced forces on the limit switch plate;
- There was insufficient preventive maintenance or inspection of this area.
What was the cause
Our member noted the following:
- The equipment was not being used as it was originally designed;
- The maintenance schedule recommended by the crane manufacturer, was not adequate.
Lessons
- Testing of the limit switches during a third-party thorough examination, though providing satisfactory results, could prove misleading;
- Complicated access to the boom tip does not allow proper inspection of these and other integrated elements of this 900T crane.
Actions
- Work with the crane manufacturer on a new design of the limit switch plate;
- Amend preventive maintenance schedule and inspection program to include more frequent assessment;
- Look at other vessel cranes for any signs of potential weak points on the limit switches.
Members may wish to refer to:
Safety Event
Published: 13 November 2023
Download: IMCA SF 26/23
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.