- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Join the global DP Community at the IMCA DP Conference in Amsterdam. 21 and 22 May. Book now
- Register your interest for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands.
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
Incorrect measurement and markings on divers umbilical
What happened
During a diving operation it was seen that the colour distance markings on the divers umbilical were not the same as stated in the diving contractor’s Diving Operations Manual. The dive was stopped and the umbilical length/markings were checked. When the umbilical markings were measured it was found that not only were the distance markings using the wrong colour code system, but also, the datum point for measurement was also incorrect. The contractors Diving Operations Manual stated the umbilical datum (zero) was from the divers end of the gas hose. The umbilical had been measured from the D ring.
No-one was harmed, but there was lost time while the umbilicals were checked, measured and and correctly marked.
What went wrong?
- It was not clear who was who was responsible for the checking the umbilical distance markings for accuracy – as a result this was not checked.
What were the causes of the incident?
Our member notes that the dive team were complacent:
- The divers and supervisor knew that the marking colour system was incorrect but did nothing to correct it;
- The dive team should have known that the distance markings were in the incorrect position as recently they had changed the markings on other umbilicals.
Actions
- All diving umbilicals were checked for:
- Correct colour code marking (as stated in contractor’s diving manual);
- Measurement from the gas hose end not the D ring (as stated in contractor’s diving manual).
- The supervisor and divers underwent refresher training and behavioural training.
- During DESIGN audit all umbilicals should be laid out alongside each other with a 50m tape so the auditor/supervisor can check for accuracy.
Lessons learned
- When a diving job is mobilised or new umbilicals are received on site, any existing marking method on the umbilicals should be checked against the company standard. A notice at the tending point, if practical, should state what the company manual marking system is, as well as any safety critical measurements to the nearest thruster or hazard;
- It was noted that DESIGN doesn’t allow for accuracy of distance measurement. [IMCA D 023 only states that umbilicals should be marked ‘At least every 10m using a recognised system’. The contractor’s manuals should state what their recognised system is. Their induction process should convey this to those that need to know.]
Members may wish to refer to:
Safety Event
Published: 30 March 2021
Download: IMCA SF 09/21
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.