- Working in DP? Explore the recent changes announced by the Nautical Institute
- Check out our calendar and meet with us at upcoming industry events
- Registration open for IMCA Lifting & Rigging Seminar 2023
- Join us at our in-person Europe & Africa Regional Meeting in Rotterdam
- Iain Grainger announced as new CEO of IMCA
- Great speaker line up for our Safety Seminar in June 2023
IOGP: Dropped object with potential for injury – riser release
What happened
IOGP have released Safety Alert 334 relating to a dropped object incident during drilling operations on a Jack-up Mobile Offshore Drilling Unit. Following running of the completion in a subsea well drilled from the jack-up, it was necessary to recover the 16″ riser.
While recovering the 16″ riser to surface, a drill-pipe deployed anchor tool, which was set inside the riser, prematurely released dropping the Riser approx. 14m and causing damage to the Subsea Wellhead Housing (WHH) sealing face. There were no injuries.
The anchor tool had been pull tested to 40K lbs to confirm engagement prior to releasing the riser.


What went wrong
The load rating of the drill-pipe deployed anchor tool in operation was not as per advised value and it subsequently failed when a relatively modest load was inadvertently applied. (The tool prematurely released at around 35K lbs overpull, rather than the 114K lbs rated overpull).
Actions and recommendations
The damage to the wellhead sealing face was subsequently addressed and confirmed satisfactory.
IOGP recommends that during recovery of casing or riser, that the slip mechanism of the anchor tool is energised constantly by applying pressure and that the shear pins and ratchet mechanism are not solely relied upon as a means to ensure tool engagement.
Members may wish to refer to:
Safety Event
Published: 12 May 2022
Download: IMCA SF 12/22
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.