Listing of crew boat due to water ingress
What happened?
During her first voyage after drydocking, a crew boat started to list. A bilge alarm signal was received on the bridge, informing that there was water inside starboard side void space #1. Following this, starboard side void space #1 was checked and it was confirmed that there was water present. At the same time the Chief Engineer inspected the void space and observed that the main discharge non-return valve was not installed improperly, and its gasket was not properly sealed. The other drain valve, placed between the forepeak and void space #1, was not installed at all and found lying nearby. The automatic bilge pump, which should have started immediately after the alarm was raised, had not started.
The portable fire pump was used to pump the space clear. At this point the vessel was listing heavily owing to some 2 cubic meters of water in the void space.
What went wrong?
- The crew boat had been in drydock before this voyage; important matters were not noticed before the vessel was launched:
- the non-return valve gasket in starboard side void space #1 was damaged
- the valve in the bulkhead between starboard forepeak and starboard side void space #1, was not installed;
- The bilge alarm signal was only a flashing light and not an audible sound alarm;
- The automatic bilge pump, which should have started immediately after the alarm was raised, had not started because the control button on the panel was in the manual position, which prevented the system from starting.
What were the causes?
There was no post-drydock maintenance inspection or dedicated testing to ensure that everything done in drydock was done properly and completely.
What actions were taken? What lessons were learned?
- Developed a pre-sail checklist of all and any critical equipment or systems (bilge systems, fire detection systems, alarms, navigation systems, propulsion and steering systems) to be checked as being in working condition before departure;
- Ensure equipment maintained, repaired or installed during drydock is physically checked and verified as working correctly.
Members may wish to refer to:
Safety Event
Published: 4 September 2019
Download: IMCA SF 21/19
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.