Loss of position of DP DSV
A member has reported that a DP diving support vessel was in the midst of a diving operation when it rapidly moved off location by some 107 metres from the work site. Two divers were locked out at the time. Diver 1 was working while diver 2 was at the bell on the guide weight. The effect of the force was such that diver 1 could not return to the bell on his own, nor could Diver 2 manage to haul him back via the umbilical. Once recovered to the bell, the diver, overcome with carbon dioxide toxicity as a result of overbreathing inside the helmet, began to vomit almost immediately upon having his helmet removed. He was settled down, put on BIBS and gradually recovered.
The company’s investigation concluded that the ‘run off’ was attributed to the effects of a Soliton. A full description of this phenomenon can be found at citeseer.ist.psu.edu/hsu00nonlinear.html (also see falkirk-wheel.com/edinburgh/information/john_scott_russell.html. However, by the simplest definition they are subsea waves of significant risk potential for diving and ROV operations. Detection by slight surface irregularities with either the naked eye or radar is possible. They tend to be seasonal and, although their direction of travel is somewhat predictable, reliance on direction alone as a precaution is not advised.
The company carried out a risk assessment and made recommendations for operating in waters of known Soliton activity as follows:
- When feasible, schedule work for low season Soliton activity;
- Seek local knowledge and experience with regards to expected activity levels;
- The vessel heading should be into the direction of the most likely Soliton approach regardless of optimum heading for DP or other environmental considerations;
- A dedicated competent person shall remain on radar watch at all times during critical work phases;
- Radar shall be tuned to optimise potential to see approaching Soliton, setting the sensitivity/gain to reduce wave scatter;
- Break away or quick release lines should be installed on all down-lines;
- Facility to overboard the supply end of tool umbilicals with buoys attached should be provided;
- Clear runs for overboard lines on deck should be established and maintained;
- When feasible, two divers should be working together at all times;
- The DP operator is to be alerted when the divers have entered a structure or confined area;
- Optimise control at subsea structure positions;
- Divers should be immediately alerted of all anomalies;
- No diver ‘turn arounds’ if attached to fixed structures in known Soiliton areas.
Safety Event
Published: 1 December 2004
Download: IMCA SF 10/04
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.