- Registration open for IMCA Lifting & Rigging Seminar 2023
- Registration open for IMCA DP Conference 2023
- Check out our events calendar and meet with us at industry events
- Window for submission of IMCA Contractor Members Safety Statistics is now open
- See IMCA in action
- Last few days to enter IMCA Awards
Loss of subsurface buoys
A member has reported an incident in which a number of subsurface buoys – used as part of the anchoring system for a semi-submersible accommodation unit – broke loose and drifted away. Due to operational restrictions on certain fields it had been necessary for certain operations to add fibre inserts, wire inserts and/or subsurface buoys to keep anchorlines over pipelines and the concrete base structure of fixed platforms.
For two such operations the field layout was such that these buoys were underwater when the submersible accommodation unit was stood off from the platform, whereas when the submersible accommodation unit was alongside, the rigging of the anchor chains meant that some of these buoys came close to the surface.
Mooring of submersible accommodation units needs to ensure sufficient clearance to pipelines both in alongside, gangway-connected mode and in stand-off position when the rig is winched away from the fixed platform.
Since the submersible accommodation unit was in the alongside position most of the time, these buoys were subject to wave loads throughout the operation. As a result, on both these operations some of the buoys close to the surface broke loose and drifted away.
The company developed an alternate technique using ‘chain through’ type buoys, which improved the operation of buoys close to the surface. The mooring chain passes through the centre of the buoy and is secured on each side. This removes the need for a pennant,which is often a weak link, and also places the buoy much deeper and clear of surface wave action.
Safety Event
Published: 14 August 2007
Download: IMCA SF 07/07
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.