LTI: Hand injury during diving operations
A member reports a serious hand injury suffered by a diver working in the water on floating hoses at an SPM (single point mooring). Two divers were working on unbolting the flange on a floating hose on an SPM, one on either side of the hose. They were working together on the same bolts, one using a pneumatic impact wrench, the other, a flogging spanner. One of the divers started to loosen a bolt using the air tool, before the other diver was braced and ready. The flogging spanner held by the other diver jerked rapidly and trapped three fingers of his left hand between the metal plate and flogging spanner, causing a serious injury.
The injured diver was evacuated by small boat and taken to hospital. There were no broken bones but some stitches were needed, following which he was 14 days off work.

What were the causes?
Our member noted the following causal factors:
- poor communication;
- inattentiveness and lack of awareness;
- Procedures not clear/procedures not followed;
- Being in an unsafe position or “in the line of fire”;
- Feeling time pressure to finish the job.
Lesson learned
- Stop and think before you start – hold a toolbox meeting, make sure the task is properly risk assessed;
- Take care how tools are held, and keep yourself out of your own and others’ line of fire;
- Consider the use of extensions to tools or different tools, or different ways of doing the job, if that keeps you out of the line if fire.
Members may wish to refer to
Safety Event
Published: 2 June 2021
Download: IMCA SF 15/21
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.