- Enter the IMCA Awards 2024: We\'re looking for outstanding Safety, Sustainability, and GHG projects.
- IP Code: Mandatory Code enters into force on 1 July. Make sure your company is up to speed with the changes.
- Early Bird tickets available for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands. Members can save £400.
- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Now booking. Join the Lifting and Rigging community at our Technical Seminar in Amsterdam. Thursday 12 September 2024
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
LTI – person fell from step ladder
What happened
A worker fell off a 2-step ladder/hop up and was injured resulting in an LTI. A tool required some maintenance before going into storage after use. To gain access to the tool and comfortably carry out the task, the worker needed to stand on a 2-step ladder/hop up.
While the worker was on the 2-step ladder/hop up, the vessel hit a wave and pitched, and this caused the worker to lose balance and fall. The step ladder/hop up went to the right and the person fell to the left struck their ribs on the frame of the tool and then fell to deck. In pain, the worker went to see the vessel medic, who after assessing the situation, transferred the worker ashore for further assessment and treatment. The diagnosis was a fractured rib. The worker was unable to return to work and went on sick leave.
The height from deck to the tool was 1.6m and the step ladder was 0.5m in height to the top step. At the time of the incident, the sea state was 2 m significant wave height, and the deck planks were wet.
What went wrong
- The ladder/hop up was not secured to a fixed point as required in procedures;
- The hazard/risk of using the two-step ladder had been identified in the risk assessment, but the mitigating actions were not satisfactory. The equipment was not robust enough.
Lessons and actions
- Even falls from low heights can result in serious injuries;
- Could the work have been done when the sea was calmer?
- Ensure such equipment is properly secured before use;
- An engineered solution was to be prepared, for a fabricated access point on the tool frame, to negate the use of a temporary step ladder.
Members may wish to refer to:
Safety Event
Published: 29 August 2024
Download: IMCA SF 17/24
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.