- Registration open for IMCA Lifting & Rigging Seminar 2023
- Register for IMCA DP Conference 2023
- Check out our events calendar and meet with us at industry events
- Register to attend our Safety Seminar in June 2023
- Window for submission of IMCA Contractor Members Safety Statistics is now open
- See IMCA in action
MAIB: Loss of containers overboard – task seen as routine
The UK Marine Accident Investigation Branch (MAIB) has completed a preliminary assessment into an incident where 34 containers were lost overboard.
What happened
On 31 October 2020, 34 containers were lost overboard from the general cargo vessel Francisca, near Duncansby Head in the North Sea. Francisca was on passage from Iceland to the Netherlands when severe weather conditions were encountered. The deck cargo of containers was struck by green sea forces when the vessel was pitching heavily into the waves, causing stacks to collapse and containers to be lost overboard. All but one of the containers was empty and some debris from the laden container washed up ashore. None of the containers were recovered, and the vessel suffered minor damage on deck. There were no injuries.
What went wrong?
The MAIB’s preliminary assessment found that:
- Violent pitching and ploughing into the heavy seas resulted in a rapid loss of speed and heading control, which exposed the deck cargo to green sea forces capable of overwhelming the maximum loading of the container securing arrangements;
- Regular passages between Iceland and the Netherlands meant that the vessel crew had become accustomed to operating in the often poor weather in the North Atlantic, Pentland Firth and North Sea, and this had lowered their appreciation of the significant weather-associated risks. The preliminary assessment also identified that the absence of a protective breakwater at the vessel’s bow increased the risk of cargo loss in heavy weather, and corrosion to the vessel’s deck cargo securing arrangements may have contributed to the scale of the loss.
Members may wish to review the following incidents in which weather played a part.
Safety Event
Published: 4 May 2022
Download: IMCA SF 11/22
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.