Mast head securing wire parted
A member has reported an incident in which one of the wire stays securing a mast head, parted. A deck officer on watch heard a loud metal banging sound on the monkey island deck. Immediately both the radar switched off and someone was sent to investigate. One set of mast head securing wires (the port side) had parted from the long bottle screw and the strop had become entangled with a radar scanner. As a result, there was damage to the front side (radiation side) of the radar scanner cover, and the lower lamp assembly for the main mast head lights was damaged. The entangled strop was cleared away; temporary repairs were made to the radar scanner, and both radars tried out again.
The root cause of the incident was inadequate maintenance and inspection – failure to notice corrosion and impending failure.
Our member suggested that all similar securing arrangements should be inspected and tightened periodically and renewed or replaced, as necessary. Extra attention should be paid to all lashing and securing arrangement when heavy weather is prevalent.
Members may wish to refer to the following incidents (search words: mast)
Here are included a number of incidents relating to equipment failure on masts – as strictly distinct from wires parting.
Safety Event
Published: 10 August 2016
Download: IMCA SF 21/16
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.