MSF: Disposable vape self-ignition
The Marine Safety Forum (MSF) has published Safety Alert 23-03 relating to an incident where an e-cigarette (“vape”) caused a small fire. This may be of interest to members.
What happened
A fire pre-alarm was raised on the bridge fire detection panel and accepted by the Duty Officer. Phone call immediately received from crew member to the Bridge informing that there was an incident with a disposable vape in his cabin, but that there was no immediate danger.
On investigation at the cabin in question, a slight smoke and smell of burning was noticed. The crew member explained that the disposable vape self-ignited on the table at which he was sitting in the chair with laptop on his lap. He immediately jumped and tried to extinguish burning vape with hands, but realising it was hot, automatically threw it onto his bed where the vape continued to burn on the mattress. He used two T-shirts to choke the fire.
What went wrong
- The company Smoking Policy, which forbade the use of e-cigarettes, was not followed; the company mandated that these devices should not be taken onboard vessels;
- The bedding used by the crew member in the cabin was not standard company issue, and thus did not comply with IMO SOLAS regulations.
Actions
- Ensure compliance with company policy on smoking and vaping, and the non-use of e-cigarette devices;
- Closer attention to e-cigarette devices when carrying out ISPS checks on board;
- Ensure bedding onboard is compliant with IMO SOLAS regulations.
Members may wish to refer to:
Safety Event
Published: 24 May 2023
Download: IMCA SF 13/23
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.