- IP Code: Mandatory Code enters into force on 1 July. Make sure your company is up to speed with the changes.
- Early Bird tickets available for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands. Members can save £400.
- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Now booking. Join the Lifting and Rigging community at our Technical Seminar in Amsterdam. Thursday 12 September 2024
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
MSF: Potential dropped objects – nets or tarps to cover cargo?
What happened?
Marine Safety Forum Safety Alert 20-04 describes a potential dropped object (PDO) during cargo operations. A wooden baton of the type often used to support covers attached to open topped Cargo Carrying Units (CCUs), was discovered jammed against the underside of a cargo basket.
Finding this PDO prompted the operator to carry out an assessment of the suitability and need for wooden batons on open top CCUs. Some of the assessment findings are noted here:
![](https://imcaweb.blob.core.windows.net/wp-uploads/2020/10/SF-2020-4.2.png)
What were the causes? What went wrong?
- Wooden batons are normally used to support the tarpaulin cover used on open top CCUs;
- Wooden batons are only held in place by being jammed against the sides of the open top;
- There is generally no securing mechanism holding the wooden batons in place;
- Batons need to be ‘knocked out’ before heavy cargo is lifted from the CCU by crane;
- Knocking out batons from high sided CCUs can result in the baton falling onto the persons removing it.
These findings prompted another assessment comparing the use of tarpaulins versus the use of nets as top covers for CCU’s, below are some of the assessment findings:
![](https://imcaweb.blob.core.windows.net/wp-uploads/2020/10/SF-2020-4.3.png)
The MSF safety alert concluded: Tarpaulins and batons do have their uses when required for covering cargo, but their use should always be risk assessed and evaluated against other cover types which may be readily available. The risk assessment should include but not be limited to:
- The type of cargo and the effects of its exposure to the environment;
- The manual handling issues that may be encountered by the end user;
- Consider the use of ‘cord strap’ or similar instead of wooden batons to support covers. (particularly on high sided open top units)
See here for full Marine Safety Forum Safety Alert 20-04.
Safety Event
Published: 6 July 2020
Download: IMCA SF 20/20
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.