Near-miss: Broken high pressure oxygen fitting
A member has reported that while recovering an inflated lift bag over the bow bulwarks on one of its vessels, a regulator attached to an oxygen pack was broken off at the bottle nipple on the high pressure side of the regulator. The king valve was quickly closed and there was no harm to personnel or equipment. Nevertheless, the potential hazard from a high pressure oxygen escape is obvious.
In its investigations, the company noted that the regulator and associated piping and hose had extended beyond the framework of the oxygen pack and into the work area.
The company has issued the following recommendations as a result of its investigations:
- Ensure fittings used are suitable for the task involved. Where such fittings extend the overall length before the regulator, they add leverage and therefore increase the likelihood of breakage;
- Plumb in such a way that the regulator, its associated fittings, gauges and hose reside within protective framework – ideally that of the bottle rack or quad skid. An appropriately rated brass pipe street elbow should be used after the bottle nipple if necessary, to keep the regulator and fittings within the protective framing;
- Wherever possible, bottle racks and quad skids should be positioned in such a way that regulators are away from work areas and walkways;
- If high pressure bottles must be located in a work area, it must be ensured that job safety analyses associated with the tasks in that area include the potential hazards associated with working around high pressure bottles.
Safety Event
Published: 1 October 2002
Download: IMCA SF 10/02
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.