- IP Code: Mandatory Code enters into force on 1 July. Make sure your company is up to speed with the changes.
- Early Bird tickets available for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands. Members can save £400.
- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Now booking. Join the Lifting and Rigging community at our Technical Seminar in Amsterdam. Thursday 12 September 2024
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
Near-miss: Cargo shifted in heavy seas whilst alongside platform
A member has reported an incident in which there was an unplanned movement of freight containers on a platform supply vessel. The incident occurred during rough weather whilst the vessel was engaged in deck cargo and fuel transfer alongside a platform. The vessel, which was positioned down-wind and with starboard stern quarter to weather, was hit by a sudden and unexpected squall. The vessel was designed with a low bulwark.
The weather and sea conditions at the time of the incident were wind 25 knots, swell 3m. One larger squall wave hit the stern and flooded the back deck. The water shifted one container and overturned another. The back-loaded containers had not yet been secured due to on-going back-loading.
There were no injuries, no spills, and no external damage to the containers.
Our member noted that this near miss incident was potentially very serious, and the incident has been treated as a potential fatality. The following lessons were learnt:
- The risk of abnormal waves should be taken into consideration in risk assessment and tool box talks for work, particularly when the vessel is positioned stern to weather;
- Greater emphasis should be placed on the ‘stop work policy’ – anyone should be able to stop the job, any time, when in doubt;
- A new and higher bulwark will be fitted to this and similar vessels working in these waters.
Members may wish to refer to the following incident (search words: cargo, shifted):
- Fatality during loading operations – members will note that this earlier incident is almost the same but unfortunately resulted in a fatality.
Safety Event
Published: 30 June 2016
Download: IMCA SF 17/16
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.