Near-miss: Dropped object
A member has reported a near miss incident in which a turnbuckle pin weighing approximately 2kg fell more than 12m to deck. The incident occurred on a third party construction support vessel used for pipe laying. The vessel has a gutter to guide the flexible pipe into the vertical tensioner. It is able to slew left and right to allow the flexible pipe to approach from various angles. This gutter was to be held in place using a combination of turnbuckle, chain and shackles (see photographs below.) Whilst installing the turnbuckle securing arrangement, the retaining pin of the turnbuckle was dropped more than 12m to deck. There were no injuries.
Using the DROPS Calculator as a benchmark in the classification of the potential consequences of a dropped object, our member determined that the outcome of dropping the turnbuckle pin could have resulted in a fatality





Our member investigated the incident and as a result implemented a simple secondary securing method to prevent dropped objects.
Members may also find useful information from dropsonline.com
Members’ attention is drawn to the following IMCA material which may be of assistance:
- Guidelines for lifting operations
- Lifting equipment (pocket card)
- Working at height (pocket card)
- Avoiding dropped objects (poster)
- Avoiding dropped objects (pocket card)
Safety Event
Published: 26 October 2012
Download: IMCA SF 11/12
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.