Near miss: Hose parted
A member has reported an incident in which a hose parted. The incident occurred whilst an anchor handling tug (AHT) was delivering deck cargo and fuel oil to a drill ship. Crew noticed that the hose was fouled below the water line of the AHT. Pumping was immediately stopped and the hose was blown down. The hose was then disconnected from the vessel manifold. Anattempt was made using the drill ship crane to pick up the hose but this was unsuccessful. The AHT tried to clear the hose by going closer to the drill ship. Attempts were made to use both the AHT vessel crane and the drill ship crane to free the hose, and while this was happening, the hose parted. No oil leak was observed.
Our member noted the following:
- Root cause: Floatation collars were missing on the hose;
- The parted hose could have fouled the ship’s propeller resulting in a dangerous situation;
- Lessons learnt/preventive action:
- the length and condition of the hose should be checked before work starts
- where necessary, floatation collars should be used on hoses
- willingness to stop the job needs reiterating.
Members may wish to refer to the following incidents (search words: hose, parted, fouled):
Safety Event
Published: 9 November 2016
Download: IMCA SF 30/16
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.