- IP Code: Mandatory Code enters into force on 1 July. Make sure your company is up to speed with the changes.
- Early Bird tickets available for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands. Members can save £400.
- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Now booking. Join the Lifting and Rigging community at our Technical Seminar in Amsterdam. Thursday 12 September 2024
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
Near-miss: Incorrect length retaining screws fitted on divers helmet
A member has reported a case of incorrect length retaining screws being found fitted to an Ultrajewel 601 diver’s helmet, exhaust valve cover assembly. This was discovered by vessel crew carrying out maintenance on a newly received 17C Ultrajewel 601 helmet. The jewel cover (Item 17, Part Number: DM022), retaining screws (Item 18, Part Number: FB240) had been cut down in length and as a result did not give the required thread engagement. The correct length of the screw was 35mm as indicated within the part description column.
Following the incident an inspection of the screws revealed that three of the four screws fitted had been cut back to varying lengths. The loss of thread certainly severely reduced the amount of thread available to satisfactorily clamp the exhaust valve cover assembly together. Loosening of the screws during use and the eventual separation of the jewel cover assembly could have caused a serious incident.
It is yet unknown how modified screws found their way into this location. All technicians maintaining diving equipment should be trained and competent personnel. Any technician who regularly maintains during equipment will understand fully the importance of the jewel exhaust valve integrity during operation and will also be very familiar with the required grip range of the screws involved.
![Screws highlighted in red](https://imcaweb.blob.core.windows.net/wp-uploads/2014/08/IMCASF14-14-image4.jpg)
![Screws of varying lengths](https://imcaweb.blob.core.windows.net/wp-uploads/2014/08/IMCASF14-14-image5.jpg)
Our member noted the following lessons:
- Only use correct screws when maintaining life support equipment and as supplied by the equipment manufacturer;
- Ensure that any held stock of the screw is adequately controlled to prevent migration into other stocked item locations and that storage bins or bags are clearly marked with the manufacturer’s part number;
- Only trained and competent personnel should be maintaining life support equipment; . Never modify manufacturer supplied parts.
Members may wish to refer to the following similar incidents (key words: helmet, fitting, incorrect, threads, modified):
Safety Event
Published: 7 August 2014
Download: IMCA SF 14/14
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.