Near miss: pilot ladder – side rope failed
What happened
Whilst undertaking pilot boarding operations during the hours of darkness, a side rope on the pilot ladder parted when it was being weight tested by the pilot. The pilot was not injured; however if the ladder had not been weight tested by the pilot, it could have failed whilst it was being climbed, resulting in a fall from height into the sea.
The pilot boarding operation was aborted and the vessel directed by the authorities to anchor, resulting in significant operational and commercial delays.

What went wrong – key findings
- The pilot ladder had not gone through a 30-month strength test because the requirement to do so had not been uploaded into the vessel’s planned maintenance system;
- It was known that the pilot ladder was in poor condition, but it was decided to continue to use the ladder beyond its operational life knowing that the vessel would soon be de-commissioned;
- The vessel did not carry a spare / second ladder.
Action taken
- A Pilot ladder is essential safety equipment and should always be serviceable / available for use;
- Safety critical equipment should be inspected before use and any deficiencies found should be reported and rectified;
- The defective pilot ladder was replaced with a new ladder;
- Carry a minimum of two pilot ladders and replace them every two years;
- Ensure vessel planned maintenance systems are up to date and include everything that should be included.
Members may wish to refer to
- OCIMF: Pilot ladder side rope failure: Unsafe pilot transfer
- Safe embarkation and disembarkation of Marine Pilots
- Pilot ladder safety
- Hazard hunt: pilot ladders and gangways
The following documents will be useful:
- SOLAS Regulation 23 on Pilot Transfer Arrangements
- IInternational Chamber of Shipping (ICS) Shipping Industry Guidance on Pilot Transfer Arrangements – Ensuring Compliance with SOLAS
- IMO Resolution A.1045(27) Pilot Transfer Arrangements
Safety Event
Published: 18 January 2023
Download: IMCA SF 03/23
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.