Near miss: potential fall through CTV hatch
What happened?
A passenger on a crew transfer vessel (CTV) came very close to falling down an open hatch. The incident occurred after a vessel crew change had been abandoned due to poor weather conditions for the transfer. The CTV returned to port. Poor weather conditions resulted in many passengers becoming seasick.
On arrival in port, the passengers disembarked the CTV via the personnel transfer pontoon. One passenger was lagging behind the others and then made his way back on to the vessel (to retrieve a personal bag) without alerting the vessel crew. At this point, the CTV crewman had already opened a deck hatch to retrieve equipment from below decks and was stood below deck with his head protruding through the hatch opening at deck/foot level.
After speaking to the crewman in relation to the bag he had left on the CTV, the passenger attempted to gain access to the vessel cabin via the walkway in which the hatch was open. This action had the potential to injure both the CTV crewman and the passenger. The passenger was prevented from doing so by the site representative, who thus prevented injury to two people.
What went wrong? What were the causes?
- The passenger re-boarded the vessel without alerting, or seeking the permission of the vessel crew;
- The passenger was suffering the effects of seasickness and was possibly less aware of potential hazards;
- The chain on the pontoon between the vessel and the pontoon was not replaced following disembarkation of passengers and site representative boarding;
- There was no physical barrier for the open hatch – site personnel providing barrier/lookout;
- Due to short notice and early hour of the day for the crew change, the passengers had not received a site induction but were provided with a site ‘chaperone’ and should have received a vessel induction.
What lessons were learned?
- Barriers should be in place around open hatches;
- Where possible, hatches should be opened when only vessel crew are onboard;
- All persons onboard should be informed when hatches are opened;
- Development of procedure for management of opening hatches to add to vessel SMS;
- There should be clear site and CTV induction stating that permission is to be sought before boarding a CTV;
- Physical barrier (gate) to be closed and bolted once all passengers have disembarked the CTV.
Members may wish to refer to:
Safety Event
Published: 20 March 2019
Download: IMCA SF 05/19
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.