Near-miss: ROV broke free of cargo strops during heavy seas
A member has reported an incident during bad weather in which an ROV which had been tied down broke free when the vessel was rolling heavily. The ROV started swinging on its supporting crane winch wire and narrowly missed personnel working nearby. No-one was injured; the ROV suffered slight damage.
The incident occurred whilst the vessel was waiting on weather in approximately 4m seas and 36 knot winds. The vessel was manoeuvring close to a floating production storage and offloading unit (FPSO) at the time and made a sudden turn, which caused an extreme roll. The stands upon which the ROV was stood slipped and the ROV itself moved, which caused its cargo strops to loosen. As a result the ROV began to swing on the crane winch wire, which was supporting the weight of the vehicle.
The ROV hit the bulkhead a number of times and narrowly missed two crewmen nearby. The crew managed to get the swinging ROV under control; the crane was started and the ROV lowered onto the deck, where it was properly sea-fastened and an assessment of possible damage then took place.
It was found that there had been some slight damage to the hydraulic hoses on the torque tool, which was attached to the ROV.
An investigation revealed the following:
- The immediate cause of the incident was that the existing fastenings were not adequate to hold the ROV against an extreme sudden movement of the vessel;
- Contributory factors were poor communication between bridge and back deck, poor judgement of sea conditions, and loss of concentration.
Members may also refer to Guidance on operational communications.
Safety Event
Published: 25 January 2012
Download: IMCA SF 01/12
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.