- IP Code: Mandatory Code enters into force on 1 July. Make sure your company is up to speed with the changes.
- Early Bird tickets available for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands. Members can save £400.
- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Now booking. Join the Lifting and Rigging community at our Technical Seminar in Amsterdam. Thursday 12 September 2024
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
Personal injury – burns from hot engine oil to body and face
CHIRP Maritime, an industry charity facilitating confidential incident reporting from seafarers, has published its Annual Digest 2021, which includes a number of events and incidents of interest to IMCA members. CHIRP = Confidential Human Factors Incident Reporting Programme. The aim of CHIRP Maritime is to enhance maritime safety worldwide, by providing a totally independent confidential (not anonymous) reporting system for all individuals employed in or associated in the maritime industries. This incident is one of them.
What happened
In a vessel alongside, engineers started the removing the cover of the main engine fuel oil filter. Hot fuel sprayed onto the body and face of one of the engineers. He received immediate medical attention and was then hospitalized locally for a week and then repatriated. According to the final medical report issued two weeks later, the engineer was recovering well.
What happened
In a vessel alongside, engineers started the removing the cover of the main engine fuel oil filter. Hot fuel sprayed onto the body and face of one of the engineers. He received immediate medical attention and was then hospitalized locally for a week and then repatriated. According to the final medical report issued two weeks later, the engineer was recovering well.
![](https://imcaweb.blob.core.windows.net/wp-uploads/2022/07/Screenshot-2022-07-26-150313.jpg)
What went right
- A toolbox meeting was held before the work was started, and both the supervisor and the injured junior engineer had undertaken the same task previously;
- A review of the work/rest hours revealed that the injured crew member was well rested and his working hours were within company and MLC requirements;
- A Permit to Work had been issued and all involved were wearing the correct PPE.
What went wrong
- The risk assessment was inadequate: it had been issued but it had not been forwarded to the company for review and endorsement, and did not address all of the potential hazards;
- There was inadequate implementation of the Company’s basic safety procedures.
- The filters were not isolated properly from the compressed air pipe and the isolation valves were not labelled as closed as required by the relevant work permit;
- The filters were not checked for being under pressure and draining of the filter was not carried out before opening the cover;
- The maker’s safety instructions were not followed.
Lessons learned
- Follow the safety rules through – these rules exist for your protection.
- Ensure risk assessment is thorough, effective and diligently carried out;
- Follow your company procedures, ensure that there is appropriate supervision to ensure this is done;
- Ensure that work instructions and procedures are strictly followed;
- Ensure everyone involved is fully and properly briefed on the job in hand;
- Follow the instructions provided by the manufacturer – they exist for a reason.
Members may wish to refer to:
- Engineer suffered burn injuries in engine room incident
- Two near miss incidents with a risk of scalding [second incident, “Crew were carrying out maintenance on the vessel’s engine”…]
Safety Event
Published: 5 September 2022
Download: IMCA SF 20/22
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.