- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Join the global DP Community at the IMCA DP Conference in Amsterdam. 21 and 22 May. Book now
- Register your interest for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands.
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
Potential dropped objects left on loaded cargo
What happened?
A member reports numerous instances of potential dropped objects being found on containers and equipment being loaded from port and offshore facilities.
What went wrong? What were the causes?
Items of significant weight, such as a bag of fittings weighing 15kg, loose rocks, scissors, crow bars, large pieces of wood and loose lumps of steel affected by corrosion, have all been found when loading cargo.
The primary causes were poor housekeeping and failing to conduct inspections of loads before, during and after lifting operations.
What lessons were learnt?
- Containers and equipment being loaded and unloaded have been prepared by a third party. Great care and caution should be exercised when accepting these loads;
- ALL parties in the supply chain have a responsibility to inspect loads before first lift, during transit and when unloading;
- Ensure good housekeeping on and around all containers/equipment;
- Never stand under a load;
- Establish exclusion zones during lifts.
Dropped objects from cargo are a significant source of incidents reported to IMCA and to other industry organisations including Step Change and the Marine Safety Forum (MSF), and remain a grave concern.
Members may wish to refer to the following incidents:
Safety Event
Published: 20 February 2018
Download: IMCA SF 04/18
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.