- IP Code: Mandatory Code enters into force on 1 July. Make sure your company is up to speed with the changes.
- Early Bird tickets available for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands. Members can save £400.
- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Now booking. Join the Lifting and Rigging community at our Technical Seminar in Amsterdam. Thursday 12 September 2024
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
Punctured welding hose flash fire
An incident has come to IMCA’s attention in which a punctured welding hose caught fire. The incident occurred during ‘routine’ use of an air operated grinder on an offshore vessel. The pipefitter/fire watch saw flames coming from the acetylene hose, told his colleague to stop grinding, isolated the gas supply and used a fire extinguisher to put out the flame.
No-one was harmed, the worksite was secured, and the incident was reported to the supervisor who stopped the work. A safety stand down was immediately held. There was no injury and no property damage other than to the hose.
The investigation revealed the following immediate causes of the incident:
- Poor practices of routing and protecting hoses had subjected them to damage;
- The acetylene hose was connected and run out in the vicinity of a workshop and subjected to uncontrolled sparks. Escaping gas was ignited resulting in a flash fire.The root causes identified were:
- The nearby workshop was not designed to prevent or control heat and spark release;
- The hose was of inferior quality and had been poorly treated;
- The hose was recently brought into service and already sustained damage resulting in the escape of acetylene gas;
- Pre and post inspections had not been adequately carried out. Had they been completed, this would have raised concerns about the structural integrity of the hose.The following corrective actions were suggested:
- Provide adequate blinding/coverings in the nearby carpentry workshop to prevent sparks and heat from going outside of the contained area;
- Training and toolbox talk reviewing the incident and stressing cable and hose management, pre and post task inspection and removing damaged equipment from service;
- All hoses and equipment to undergo ‘routine’ maintenance inspections and be colour coded to enable personnel see the equipment is valid to use;
- Several other damaged hoses were removed and replaced;
- A pre-and post-task welding hose checklist was created and made part of the permit to work process.
Members may wish to refer to the following similar incidents (key words: fire welding):
Safety Event
Published: 14 July 2014
Download: IMCA SF 12/14
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.