Release of stored energy from coiled superloops
What happened?
A release of stored energy from a coiled superloop resulted in an injury to the person uncoiling the superloop. The member reporting this notes that this is the second such incident that they have encountered in the last year.
What went wrong? What were the causes?
In both cases, the injured person was standing in the centre of the coiled superloop releasing fastenings when the sling sprang upwards, striking the person in the face. After the first incident, certain company personnel attended a training course specifically addressing the risk of stored energy in coiled superloops and how to control these risks when uncoiling. It was then the intention that these persons would be present at third-party yards to provide advice when company coiled superloops were being uncoiled.
However, whilst there was a trained person at the yard at the time of the second incident, uncoiling by untrained yard labour took place without taking his advice.
What was the outcome for the company?
Company work instructions have been updated to include safety instruction on the uncoiling of superloops. The intention of the safety instruction is to raise the awareness of the risks involved in uncoiling superloops and how to control these risks to third parties receiving coiled superloops.
Members may wish to refer to:
- Stored energy – injury sustained whilst removing metal straps
- Guidelines for lifting operations (IMCA SEL 019)
- Line of fire (‘Be prepared to work safely’ video)
- In the line of fire (IMCA SEL 036, classic safety video)
Safety Event
Published: 30 October 2018
Download: IMCA SF 24/18
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.