Rope under tension parted on deck
What happened
A wire rope parted under tension and struck someone’s helmet. There was no injury. The incident occurred during preparation for a shore-side pull of an export cable; the cable lay vessel recovered an onshore winch wire. The rigging connection failed resulting in the parted rope striking an operator’s helmet.

The winch wire from the onshore site was connected to the cable lay vessel winch via recovery rigging. The supporting workboat hauled the onshore wire to make the connection with the cable lay vessel wire. When the connection was confirmed, the Shift Supervisor on the cable lay vessel gave the order to pay in and recover the connected winch wires. The Shift Supervisor, positioned at the top of the chute platform, noticed a polypropylene rope was attached to the rigging which was not part of the approved rigging arrangement. The polypropylene rope suddenly came under tension, parted, recoiled and struck the Shift Supervisor’s helmet. The helmet shell separated from the inside webbing. No-one was harmed.
What went wrong?
- Nine persons were on the cable lay vessel deck at the time, all neglecting the ‘Line of Fire’ Life Saving Rule;
- The crew on the workboat did not follow the company approved rigging arrangement;
- There was no supervision on the workboat to ensure the approved procedure was followed;
- There was a language barrier; the workboat crew only had minimal English.
Actions
- Follow the Life-Saving Rules; do not place yourself in the line of fire;
- Ensure better close collaboration between third-party vessels:
- Confirm that procedures have been reviewed by crews
- Ensure they attend Hazard Identification and Risk Analysis (HIRA) meetings
- Ensure that they are fully familiar with the task plan on site.
- Ensure adequate levels of supervision for the task in hand;
- Where appropriate, ensure bilingual documentation is available for key documents and that a translator is available who is familiar with the task.
Members may wish to refer to:
- Stored energy near miss: Person nearly hit by equipment caught during light daughtercraft operations
- Dutch Safety Board: fatality when mooring line snapped
- Fall from height during yard visit [Many similar causal factors including language difficulties.]
Safety Event
Published: 15 October 2021
Download: IMCA SF 28/21
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.