Serious personal injury and uncontrolled lowering of final splice bight
An incident occurred during a cable laying operation, while in the process of slipping the final splice in 4,900 metres of water. As the cable end came off the top of the drum, the pre-form stopper began to slip along the cable until it pulled off the end. At the same time, the Bosun had moved into the cable line, from a position of safety, to clear away some tools on the deck. The end of the cable, together with fittings and the pre-form stopper hit the deck head above the cable diverter and struck the Bosun, wrapping around him and dragging him off, knocking him to the deck and over the side, seriously injuring him.
The investigation discovered that only one pre-form stopper had been present. The contractor has elected to issue instructions that two pre-form stoppers should always be applied to non-armoured cable, with equalising wire between the stoppers and a ball bearing swivel between the equalising wire and the rope.
Safety Event
Published: 1 March 1998
Download: IMCA SF 02/98
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.