Shackles in rigging assembly below required safe working load (SWL)
A member has reported that during a recent a recent spot check on a lifting bridle it was identified that a 17T shackle had been fitted instead of a 30T shackle. The preassembled lifting bridle included 3 x 30T shackles (Crosby G2140) and 1 x 17T (Crosby G2130) instead of 4 x 30T shackles. The certificate for the 17T shackle was cross checked against the identification number on the attached tag plate and showed the shackle SWL as 30T. The shackle was removed and replaced with a 30T shackle (30T working load limit (WLL) embossed).
Although the shackles are almost identical in size, differences in the material grades determine the WLL. Both the material grade and WLL are embossed on every shackle. It appears that an error was made during the certification process by the supplier where a 17T shackle had been certified (ID tag attached with common certificate number) as part of a batch of 30T shackles.
This unsafe condition reinforces the requirement to conduct a pre-use inspection of lifting equipment prior to commencing the lift.

Safety Event
Published: 19 July 2011
Download: IMCA SF 07/11
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.