Suspected case of Legionella onboard vessel
What happened?
Two cases of “acute pneumonia in severe form” were identified on a survey vessel with 42 persons onboard, including crew and client’s representatives. The client’s health team assumed it to be a case of Legionella. The vessel went into port and both affected personnel were evacuated and sent to a medical clinic for examination.
What were the causes?
Legionella infection is caused when bacteria gains entry into the respiratory system. This can occur from water suspended in air in the form of a fine mist as created by showers or tap sprays.
Well maintained water tanks, pipe work, pumps and hoses, along with good water management practices can help control the legionella bacteria.
Corrective Actions
- Legionella and throat culture tests were arranged for all personnel onboard;
- Swab tests were taken from the ventilation systems in the cabins of the two affected personnel;
- Deep cleaning of all vessel cabins and washing and cleaning of all ventilation air grates (as well as pipes);
- Appropriate cleaning chemicals were passed through the ventilation system by a specialized contractor so that air flow could assist in the disinfection process. Treatment of portable water tanks was arranged also;
- Arranged appropriate cleaning/chlorination of cabin shower heads at quarterly intervals.
Medical test reports later confirmed that:
- The two persons were not infected with Legionella. They were diagnosed with acute respiratory infection and appropriate medicines prescribed;
- There were no signs of Legionella disease confirmed onboard.
Members can search the IMCA catalogue for further LTI related incidents by using the search bar on our safety flash webpage:
Members may wish to review the following:
Safety Event
Published: 18 December 2018
Download: IMCA SF 28/18
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.