Tombarra fall wire fatality: Updated reports
The UK Marine Accident Investigation Branch (MAIB) has published two updated reports on the investigation of the fatality of a rescue boat crewman on board Tombarra in February 2011.
The first is Report 19A/2012 Part A -The failure of the fall wire (maib.gov.uk/cms_resources/TombarraPartA_Report.pdf).
The following key issues are highlighted in this report:
- A rescue boat fell 29 metres killing one of the boat’s four crew;
- The boat’s fall wire parted following the failure of a proximity switch which enabled the davit’s winch to overload the wire;
- A holistic view of the design, approval and compatibility of davit and winch systems is essential to prevent individual components of the system being overstressed to the point of failure;
- It is essential that ships’ crews always test safety devices before use and do not rely on them for their safety.
- The rescue boat was found to be 50% overweight. During the investigation, other rescue boats were found to be up to 110% overweight;
- The additional weight was due to water ingress through the hull and subsequent entrapment in the boat’s internal stiffeners and foam-filled compartments buoyancy spaces, and could only be removed by drilling holes or removing the deck;
- The crew were unaware that the boat was significantly heavier than designed;
- The number of other rescue boats, made by differing manufacturers which have also been found to be overweight, indicates that the problem of water entrapment within buoyancy spaces is widespread and potentially extends to lifeboats and leisure craft;
- The investigation identified the need to weigh the boats on a regular basis.
The second is Report No 19B/2012 Part B -The weight of the rescue boat (maib.gov.uk/cms_resources/TombarraPartB.pdf).
The UK MAIB’s earlier preliminary findings and updated findings were published inFall fatality during platform abandonment and Failure of fall wire – update to safety flash 05/11.
Safety Event
Published: 11 October 2012
Download: IMCA SF 10/12
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.