- Registration open for IMCA Lifting & Rigging Seminar 2023
- Registration open for IMCA DP Conference 2023
- Check out our events calendar and meet with us at industry events
- Window for submission of IMCA Contractor Members Safety Statistics is now open
- See IMCA in action
- Last few days to enter IMCA Awards
Use of pre-mixed nitrox gases
An incident has been brought to IMCA’s attention where premixed cylinders or quads of nitrox gas may not have had the necessary oxygen content to sustain safe diving and the cylinder or quad may not, in fact, have contained the mix that was indicated on the label and/or accompanying paperwork.
In a recent near-miss incident, a contractor was conducting diving operations using third-party-supplied cylinders and quads of premixed nitrox via a dive control panel arrangement that fortunately included in-line gas analysers.
In a situation where the nitrox mix should have had a 36% oxygen content, during the operational monitoring process the contractor chose to immediately suspend diving operations when a reading of 32% oxygen content was observed by the panel operator and supervisor. Further tests were conducted which verified that the nitrox gas supplied was not the correct gas mix for safe diving operations.
During subsequent testing of both the cylinders and quad contents, an oxygen content of approximately 15% was observed in some cylinders, a percentage well below that specified and at a level where a serious incident could have resulted. Since there is an obvious increased risk of decompression sickness when the oxygen content of the nitrox mix required is less than the oxygen content specified in the decompression tables being used, attention to detail is critical. In this instance it was only the vigilance of the contractor that detected the problem before an incident occurred.
The following lessons may be drawn:
- The mix of the gas should be clearly specified to any third party supplier and knowledge of their quality assurance system known and understood before an order is accepted for operational use;
- Cylinders and quads delivered from third parties should have their gas content analysed after delivery and certainly before first use on site;
- The use of panel mounted in-line gas analysers has proved to be extremely beneficial in this case;
- Particular attention should be paid to individual bottles within their racks as any bad mix could dilute easily into the pack and not be found. If such a bottle were utilised as a single source for supply it would be particularly dangerous.
Safety Event
Published: 7 September 2009
Download: IMCA SF 13/09
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.