- IP Code: Mandatory Code enters into force on 1 July. Make sure your company is up to speed with the changes.
- Early Bird tickets available for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands. Members can save £400.
- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Now booking. Join the Lifting and Rigging community at our Technical Seminar in Amsterdam. Thursday 12 September 2024
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
Vessel made contact with quay
A member has reported an incident in which a vessel landed heavily on the quay, causing damage.The incident occurred during the hours of darkness, during shifting of the vessel’s position at the berth. The shifting plan was discussed between the Master and the pilot and information was exchanged. The vessel’s position was agreed to be adjusted to meet the terminal’s requirements for cargo offloading. Two tugs arrived and the shifting operation began. The main engine and bow thruster were on standby and used as required.
The operation proceeded as planned and the vessel came gently to a stop, parallel to berth about 2 meters out. At this time, an unloading boom needed to be deployed. It was found that this could not be deployed whilst the vessel was in this position, as there was fixed equipment on the berth in the way. After further adjustment of vessel position, the unloading boom was swung out.
The Master requested that the Pilot take extra care as the vessel was brought alongside. However, as the vessel was being pushed towards the berth both tugs failed to push in harmony. The after tug pushed more and instead of landing parallel to the berth, the vessel’s port quarter landed heavily on the quay near Bollard 7. The vessel’s port side shell plating was damaged near a fuel oil tank, and there was damage to the concrete of the quay itself.
Our members’ investigation noted the following:
- Although the shifting plan was discussed verbally, there was no evidence of a risk assessment being carried out for this operation;
- The Master and the Pilot had not agreed on a working language during their discussion and information exchange;
- The Pilot was using French rather than English to instruct the crew of the tugs;
- The Master and bridge team did not intervene with the Pilot to verify commands given to the tugs in French.
The immediate causes were determined to be:
- The Pilot misjudged the tugs pushing power;
- The pilot was giving instruction in a language which was not understood by the bridge team.
A causal factor was inadequate communication – the Master failed to intervene with the Pilot when instructions to the tugs were given in a language he did not understand.
The root causes were identified to be:
- Risk considered tolerable – this was considered by the Pilot to be a routine recurring task;
- Inadequate Standards – there were no company procedures to cover the situation, particularly with regard to the working language on the bridge during navigational operations where Pilot/tug assistance is required.
Our member took the following preventative actions:
- Remind Masters that they should override the Pilot’s instructions if they are considered to be incorrect or unsafe;
- Establish formal working language for ship’s movement at all times including berthing/un-berthing operations;
- Ensure compliance with guidelines on relationship between Master, Officer of the watch (OOW) and Pilot.
IMCA Safety Flash 10/16 covers mooring and cargo handling incidents. Incident 1 –Vessel in collision with floating dock – is very similar to this incident and may be of interest to members.
Safety Event
Published: 6 December 2016
Download: IMCA SF 33/16
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.