Warning signs not respected
A member has reported that an electrician was on the deck of a semi-submersible crane vessel and was going to the lower part of the J-lay tower (clamp area) in order to install lighting necessary for the night time working activities.
To gain access to the tower he used a scaffold which had been an alternative route to it and which was directly connecting the vessel bow to that level just above the clamp area.
However, due to operational requirements, the scaffold had been disconnected from the tower and pulled toward the deck of the vessel. To indicate the hazard a white rope had been put close to the entrance, as well as a red tag that forbade the use of the scaffold.
Since the scaffold was not secured, it overturned under the weight of the electrician causing him to fall 13.8 m down, hitting the handrail of the narrow walkway located between the vessel and the clamp area. The electrician suffered fractures of his right arm and right leg. In addition, some of the pieces of the collapsed scaffold caused minor injuries to a scaffolder who was working in the clamp area.
Cause of the accident:
Despite all tool box talks held on board and the safety signs installed on the scaffold, the injured person by-passed the prohibition signals placed on the scaffold, risking his own safety and the safety of other employees.
Company’s corrective action:
- Tool box talks with all personnel about the safe use of the scaffolds and respect of the warning signs.
- Ensure installation of more evident safety signs.
- Dismantle scaffolds immediately as soon as they become unnecessary.
Safety Event
Published: 1 July 2002
Download: IMCA SF 05/02
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.