Winch brake failure
A member has reported an incident in which an ROV winch brake failed, leading to the uncontrolled movement of an ROV as approximately 800m of umbilical ran off the winch drum in less than 90 seconds. The incident occurred whilst the ROV was being lowered to 1843msw depth. It was then raised to a final stopping point of 1813msw (30m off bottom), and the winch was shut down. Within moments the winch started to slip and pay out small amounts of umbilical. This quickly developed into an out of control run-away on the winch drum, resulting in all, approximately 800m of umbilical running off the winch drum in less than 90 seconds. When the winch finally stopped there was 225m (approximately 3/4 of the last layer) of umbilical left on the winch.
During those 90 seconds, the ROV control room (on the same deck as the winch) was evacuated, the bridge was notified by phone and clear communications, and the vessel was ordered to move away from any subsea assets with utmost haste. The vessel moved 18m to the north.
All electrical power to the ROV system was isolated. Due to friction, or some other unknown element, the winch drive motor caught on fire. The ROV crew extinguished the fire with portable extinguishers. The area was barricaded, a fire watch posted and all non-essential personnel except for the fire watch and his runner were cleared from the area.
There were no injuries.
![Winch motor after fire](https://imcaweb.blob.core.windows.net/wp-uploads/2015/04/image8.jpeg)
![Winch motor after fire](https://imcaweb.blob.core.windows.net/wp-uploads/2015/04/image9.jpeg)
![Winch motor after fire](https://imcaweb.blob.core.windows.net/wp-uploads/2015/04/image10.jpeg)
Our member’s investigation noted the following:
- A preliminary on-site investigation of the failure by the manufacturer was conducted with no conclusive root causes identified. The failed winch brake was shipped to the manufacturer for a detailed analysis to determine root cause(s);
- Following extensive testing and analysis, the manufacturer identified the most likely root cause of the run-off was probably a blockage in the winch secondary brake release line;
- Given the damage to the winch the incident investigation could not determine a definitive root cause but were able to establish through elimination a probable cause for the occurrence. A series of actions to prevent occurrence had been established these were included in the manufacturer’s technical bulletin.
The following actions were taken:
- The manufacturer released a service bulletin to all operators of winches with this type of brake advising them of two checks to perform to prevent recurrence:
- One check, the Brake Release Line Check, verifies that the release pressure was dropping in the specified time and should be performed every time the brake release line or hydraulic power unit (HPU) controls were serviced;
- The second check, the Motor-to-Brake Load Transfer Check, verifies that the load has fully transferred from the hydraulic motor to the failsafe brake and should be performed before the HPU was purposely shut down while the winch is under load.
Members may wish to refer to the following similar incidents (key words: winch, brake, failure):
Safety Event
Published: 2 April 2015
Download: IMCA SF 05/15
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.