Pipe under tension on a reel

  • Safety Flash
  • Published on 16 February 2007
  • Generated on 18 June 2026
  • IMCA SF 01/07
  • 1 minute read

A Member has relayed a report of an incident involving a reel containing pipe under tension at a third party’s onshore facility. 

What happened?

An employee, unaware that the pipe was under tension, removed the ratchet strap securing the pipe on the reel. When the tension was released, the pipe sprang out and struck the employee above the left eye, causing a wound which required subsequent medical treatment.

There was a caution label warning that the pipe was under tension. However, this was on the flange of the reel and not clearly visible.

Photographs relating to this incident are shown below (swipe for more).

How the pipe was secured on the reel using a ratchet strap

how the pipe was secured on the reel using a ratchet strap

The unwound reel after the ratchet strap was removed and the stored energy released

the unwound reel after the ratchet strap was removed and the stored energy released

The warning label that was on the flange of the reel

the warning label that was on the flange of the reel

Actions

The following actions were recommended:

  • Tensioned pipes should be tied off/secured using either a mechanical ‘U’ clamp or pipe clamp with a ratchet strap (or rigging) being used as a back up.

  • Any warning signs should be attached to the pipe end or near the securing mechanism such that they are clearly visible to all personnel who will be handling the reel and pipe.

Latest Safety Flashes:

Arm injury – need for focus on safe isolation and task control

A worker sustained an arm injury while troubleshooting a malfunctioning garbage compactor.

Read more
Floodlamp causes scaffold board to start smouldering

Workers on the accommodation deck noticed light smoke emanating from a nearby scaffold structure.

Read more
Lamp fixture fire in office cabin

A fire broke out in a ceiling lamp fitting in a cabin on a vessel.

Read more
BSEE: Prevent fires by inspecting cords, plugs and welding leads before use

The United States Bureau of Safety and Environmental Enforcement (BSEE) has published Safety Alert 515.

Read more
More positive stories

Some more stories of good things happening – what went right.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.