NTSB: Engine room fire – put things back properly after maintenance

  • Safety Flash
  • Published on 12 January 2026
  • Generated on 13 April 2026
  • IMCA SF 01/26
  • 2 minute read

The National Transportation Safety Board of the United States (NTSB) has published report MIR 25-29 relating to an engine room fire on board a dredging vessel.

What happened?

A fire broke out in the engine room. Two crew members were in the machinery control room when the fire started: one escaped, and the other was removed by the shipboard emergency squad and later pronounced dead at a local hospital. After reporting no active fire and removing the crew member, the crew verified that the engine room was sealed and released the fixed gas fire extinguishing system. No pollution was reported. Damage to the vessel was estimated at US$18 million. 

What was the cause?

NTSB determined that the probable cause of the engine room fire was lube oil spraying from an auxiliary diesel engine (generator) and igniting off a nearby running diesel engine.
This came about because:

  • A vital plug was not reinstalled after routine maintenance in accordance with the engine manufacturer’s instructions.
  • There was no thorough inspection of the engine before initially starting it after maintenance.

What do we learn?

After maintenance:

  • Be careful of automatic control of equipment – as far as is appropriate and practical, make a local test start of machinery after any changes or any maintenance.
  • Ensure there is diligent inspection of machinery to ensure it functions as expected.
  • Ensure that all components have been reinstalled properly. 

Starting up engines locally, rather than remotely, gives crew members the opportunity to immediately verify that the engine is operating satisfactorily (to the manufacturer’s specifications) with no visible fuel, lube oil, or water leaks, and has no atypical noises or vibrations that require it to be stopped.  

Latest Safety Flashes:

MAIB: Sinking of tug Biter with loss of two lives

MAIB has published Accident Investigation 17/2024 relating to the girting and capsize of tug Biter with the loss of two lives.

Read more
Dropped object – strop parted over sharp edge

A cylinder was lifted to a height of approximately 6 metres over deck of the vessel, the sharp steel edges of the cylinder cut through the firehose protection and caused the strop to part.

Read more
Person injured when pry bar slipped

A crew member who was applying downward pressure to their pry bar to lift a track, fell towards the deck when the pry bar slipped.

Read more
MSF: High potential near miss during FRC maintenance

The Marine Safety Forum has published Safety Alert 26-01 relating to an incident where there was an unplanned lowering of an FRC to the sea

Read more
BSEE: Crane incident leads to serious facial injuries

BSEE has published Safety Alert 512 relating to a crane incident during well abandonment which led to a worker being struck and suffering serious facial injuries.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.