Transponder pressure relief system failure

  • Safety Flash
  • Published on 1 March 2005
  • Generated on 30 November 2026
  • IMCA SF 03/05
  • 1 minute read

Whilst reviewing its test and repair procedures for transponders, a member has reported that a serious flaw was discovered in the pressure relief mechanism in two out of three Kongsberg transponders tested. 

Such transponders are in common use across marine operations world-wide and it is possible that some could exhibit the same fault whereby internal pressure build-up would not be able to be vented automatically.

It appeared that the pressure relief mechanism was locked in place and would not operate, possibly due to an assembly fault by the manufacturer.

Pending detailed instructions from the manufacturer, the contractor instructed its personnel not to disassemble any such transponders.

Kongsberg has been exploring the matter, relating to the RPT model transponder (which went out of production in 2002) and has now issued a technical bulletin on the subject, a copy of which is attached below.

Safety Flash 03 05 3
Safety Flash 03 05 4
Safety Flash 03 05 5
Safety Flash 03 05 6

Latest Safety Flashes:

LTI: serious finger injuries during crane operations

The boom of a 12 tonne crane moved towards the pipelay tower, and trapped the spotter’s left hand against a handrail. 

Read more
Finger injury caused during maintenance of rotating machinery

Although the electrical supply was isolated, a V-belt continued to rotate due to residual mechanical energy.

Read more
MSF: Serious hand injury (LTI) – failure to Isolate

Chief Engineer attempted to adjust an air filter housing clamp, and his hand entered the exposed hazard zone, contacting the rotating turbocharger fan.

Read more
MSF: Someone’s finger trapped in the door

The Marine Safety Forum (MSF) has published Safety Alert 26-15 relating to a finger caught in a door.

Read more
Hand injuries - keep your hands clear, every task, every time

One of our Members notes a spate of recent hand injuries occurring during multiple activities.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.