Mooring rope caught in stern thruster
- Safety Flash
- Published on 10 September 2026
- Generated on 26 October 2026
- IMCA SF 16/26
- 2 minute read
Jump to:
Confusion whilst unmooring as it was being prepared for departure from port, led to mooring ropes being caught in the stern thruster.
What happened?
A vessel was preparing to depart with a pilot onboard. Local traffic control instructed the Pilot that the vessel must remain alongside until another vessel departed and passed astern, and that the vessel was not permitted to use thrusters until the passing vessel was clear.
The Pilot advised the Master to “start with the stern ropes first,” which the Master relayed to the deck crew. This wording was interpreted as an action command, rather than an instruction to prepare, resulting in the unintended release of both stern lines by the deck crew. Critically, the aft spring was already taken onboard, unnoticed from the bridge due to the aft capstan winch location and blind spot. Although the forward spring remained in place, it was later assessed that it had not been properly adjusted / tensioned, allowing the vessel to surge ahead when the stern lines were released.
With only forward lines restraining the vessel and a significant river current acting as a wedge between the stern and the quay, the vessel began moving toward another berth. The Master applied astern propulsion and lateral thrusters to regain control. During this manoeuvring, deck crew reported that a rope had gone under the stern.
Why did it happen?
- Miscommunication: An ambiguous mooring instruction was interpreted as an immediate release order, leading to premature letting go of stern lines.
- Loss of situational awareness due to blind spots and no verification of spring-line status.
- Bridge Resource Management (BRM) failure, including the lack of closed loop communication and assumption of shared understanding.
- Overreliance on informal phraseology, instead of standardised mooring commands.
What are the lessons?
- Closed‑loop communication: This is vital especially for mooring – ensure everyone clearly understands what is happening; repeat instructions back and get confirmation that this is exactly what you need to be doing. Assume nothing!
- A correctly tensioned forward spring is critical to controlling vessel movement.
- Don’t underestimate the effects of current, weather, and visibility during vessel manoeuvring operations.

Bridge view - Capstan winch located inside crash rail
Related Safety Flashes
-
IMCA SF 07/19
18 April 2019
-
-
IMCA SF 03/26
13 February 2026
-
-
IMCA SF 23/23
3 October 2023
-
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.