A member has reported two incidents involving personnel transfer using the Crew Transfer vessels (CTVs) used in the offshore renewables industry.

Incident 1 – Near miss: use of fall arrest devices during CTV personnel transfer

Whilst transferring personnel to a wind turbine generator tower during the hours of darkness in the winter months, a CTV was pushed onto the boat landing for approximately 10-15 minutes. During this time two persons were transferred safely. As a third person clipped on to the fall arrest device, a rogue wave hit the vessel. It was dark and the wave was unseen and unexpected. It lifted the CTV at least 4 metres up the boat landing. The crewman assisting the transfer instructed the transferee to quickly unclip from the fall arrest device to prevent himself from being picked up off the deck. He was able to do so, and the vessel quickly dropped to its previous level on the boat landing.

The Master immediately notified the company of the incident and stopped transferring personnel until there was an improvement in sea state and/or visibility. In due course the Master was happy that the safe transfers could resume, and operations continued without further problem.

The client issued a safety notice warning of the imminent worsening seasonal weather in their newsletter – this included additional instruction for CTV transfer during marginal weather conditions.

Incident 2 – Manoeuvring in close quarters to other vessels – crew transfer as Simultaneous Operations (SIMOPS)

A CTV was requested to attend a wind turbine generator monopile to transfer some personnel, whilst a construction vessel was nearby in dynamic positioning (DP) mode. The personnel were successfully transferred to the foundation, but as the Master activated astern gear and pulled away from the monopole, the CTV went through the thruster wash caused by the construction vessel (which was in DP mode). This caused the CTV to move in an unpredictable and uncontrollable way – the CTV passed within 4 metres of the construction vessel itself.

Diagram of incident

Construction vessels holding station using DP are now in common use in the offshore renewable industry; these vessels, which are much larger than crew transfer vessels, operate in DP mode whilst navigating close to a wind turbine generator monopile. It is not always possible for the construction vessel to move further away from the monopiles as they are generally constrained by subsea equipment such as cables, survey gear and construction equipment.

The client required that procedures be reviewed and reconsidered:

  • When personnel are not on the wind turbine generator, the construction vessel should maintain a clear distance between itself and the tower of approximately 50 m.

  • After personnel have safely accessed the wind turbine tower, the construction vessel can then move into position to complete works.

The issue of where and how to safely attach personal fall protection during transfer from one vessel to another, is one that is currently of great interest to IMCA and its members within the renewables sector, as this kind of incident has been reported several times to IMCA in recent years.

Safe transfer of personnel in general is dealt with in detail in IMCA HSS025, LR012, M202 – Guidance on the transfer of personnel to and from offshore vessels and structures.

Members may also wish to refer to IMCA M203 – Guidance on simultaneous operations (SimOps).

Latest Safety Flashes:

Cyber-attack on vessel

An oil tanker suffered a cybersecurity incident.

Read more
MAIB: Normalising of unsafe practice – fatal man overboard incident

MAIB have published Accident Investigation Report 16/2026 into a fatal man overboard incident on board a bulk carrier offshore Sweden.

Read more
Dust explosion in Bow thruster motor

Upon activation of the bow thruster, there was a loud explosion within the forward section of the workboat.

Read more
Dropped bulk bag during loading operations

A dropped object incident occurred during quayside lifting when a bulk bag failed due to incorrect loading.

Read more
Failure of sea-fastening on the leg of a jack-up barge

During a sea passage, prevailing sea conditions caused a jack-up barge to experience rolling and pitching motions.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.