Dropped pallet during forklift operation
- Safety Flash
- Published on 18 June 2025
- Generated on 21 November 2026
- IMCA SF 11/25
- 2 minute read
Jump to:
A pallet containing a load weighing 500kg dropped off a flatbed truck in close proximity to a delivery driver.
What happened?
The incident happened during unloading of the flatbed truck, which was carrying two cranes on pallets butted up against each other. The forklift truck operator attempted to offload the first one, but during this operation, the forks accidentally caught the second pallet, causing it to fall off the far side of the truck. At this moment, the truck driver had walked over to the far side of the truck, and the falling load narrowly missed him.

Forklift truck unloading pallet from truck

The fallen load after the incident
What went wrong?
Three causes were identified:
· The condition of the load - the way the pallet was positioned made it difficult to get a clean lift off the truck, and the high centre of gravity of the load made it easy to topple
· The forklift truck
- The operator did not get off the forklift truck to conduct a pre-assessment of the load or check the fork positioning
- The forks caught on the pallet behind the one that was being offloaded
- The forklift truck operator did not stop the job after initial contact when the load appeared to wobble
· People positioning
- Lack of communication/instruction to delivery driver on site
- Delivery driver moved into an unsafe position next to the load
Actions and lessons learned
· As a result of the incident the company rewrote its own procedures for ‘Safe Use of Forklift Trucks and Mobile Elevating Work Platforms’
· Ensure with suppliers that cargo and loads are packed and delivered in a safe way
Related Safety Flashes
-
IMCA SF 02/24
22 January 2024
-
IMCA SF 19/22
26 July 2022
-
IMCA SF 09/18
24 April 2018
-
-
IMCA SF 19/16
12 July 2016
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.