LTI – forklift knocked spooler bar onto person’s leg

  • Safety Flash
  • Published on 22 January 2024
  • Generated on 9 October 2026
  • IMCA SF 02/24
  • 2 minute read

While helping with spooling operations at a third-party yard, a person was injured in the lower leg.

What happened?

While helping with spooling operations at a third-party yard, a person was injured in the lower leg, when a forklift truck struck the edge of a spooler bar causing it to roll onto his legs, resulting in soft tissue damage. The injured person was working on a spooling winch, with the spooler bar positioned behind him, resting on wooden chocks. The forklift truck reversed from the rear of the spooling winch and struck the edge of the spooler bar, resulting in it rolling from the wooden chocks onto the persons’ leg. He was unable to work for four days.

  • What was expected to happen?
    • It was planned that spooler bar would be inserted into the reel.
  • What actually happened?
    • The wrong size of spooler bar was provided by a sub-contractor, and this led to the spooler bar being placed in an unsafe position in the working area of the person who was injured.

What went wrong?

  • There were only two personnel involved in conducting the operation, and the supervisor was also fulfilling the role of forklift truck operator and rigger.
  • There were no hard barriers in place to mitigate hazard of impact/collision.
  • The impact sensors on the forklift truck did not detect the spooler bar when reversing, as the sensor was positioned at the top of the forklift truck and the spooler bar was below this level.
  • The forklift truck operator unexpectedly decided to reverse the forklift truck through a congested working area with no banksman.

What went right?

  • The injured person received first aid treatment on site and was quickly transferred to local hospital for X-ray and further assessment.
forklift knocked spooler bar onto person’s leg

Actions

  • Verified that existing risk assessments for fork-lift truck operations were fully aligned with company requirements and specifically cover:
    • Access, moving the fork-lift truck, the travelling surface and obstructions at the work location.
    • Signalling and communications protocol.
  • If the fork-lift truck operator’s vision is obscured, always use a Banksman to guide the fork-lift truck.
  • Reviewed use of sensors and alarms on fork-lift trucks to mitigate impact/collision risk.
  • Subsequently, the subcontractor involved installed reversing cameras on all forklifts.

Latest Safety Flashes:

Hydraulic oil leak detected below moonpool

A hydraulic oil leak was identified below the moonpool after the worktable doors were opened.

Read more
Dropped scaffold board (kickplate) – SIF near miss

A scaffolding kickboard was accidentally dropped falling from a height of 6.5 metres to the main deck.

Read more
H₂S detected on deck

During vessel transit back to port, Hydrogen Sulphide (H₂S) was detected in the open space on the main deck.

Read more
Restoration and verification after maintenance

A missing flooring panel was identified beneath a 415V bow thruster electrical motor cabinet.

Read more
Vessel contact during materiel transfer in adverse weather

One vessel lost heading and position control because of the strong winds and swell, pushing it toward another.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.