COVID-19 Improper Risk Management

  • Safety Flash
  • Published on 2 February 2021
  • Generated on 4 November 2026
  • IMCA SF 04/21
  • 3 minute read

Where testing is carried out as part of the crew change risk mitigation process, all test results should be known before sailing.

What happened?

As part of a scheduled vessel crew change, all on-signing crew members received a COVID-19 PCR test.

Although all results were deemed negative, one test had failed to produce a valid result, and a new test was organised.

Giving due regards to the known results and following an assessment of the COVID-19 risks, marine and project management took the decision to sail, with the re-tested person effectively isolated onboard the vessel whilst awaiting the result of the PCR test.

Two days after departure, a positive PCR test result was received, resulting in the person having to remain isolated on board the vessel for 14 days.

The isolation was well managed in line with the vessel’s COVID-19 outbreak management plan and there were no further infections reported.

Where testing is carried out as part of the crew change risk mitigation process, all test results should be known before sailing

Lessons learnt

  • Sailing without receiving all PCR test results was in direct conflict with the mitigations described in the original (approved) risk assessment for the crew change.
  • The risk of having a potential COVID-19 infected person onboard was assessed by the project management team in collaboration with the marine senior officers. The outcome of the risk assessment was not presented to senior management ashore for formal review, nor for approval.
  • There was no formal management of change to ensure that senior management (ashore) were satisfied that the risks had been evaluated and would be properly managed.
  • The person concerned was required to remain onboard to satisfy the vessel’s safe manning requirements, however, during the 14-day isolation that person was not available to perform normal duties.
  • The work site was approximately 300 nautical miles from port, which could have prevented the person receiving timely treatment in the event of complications arising from the COVID-19 infection.

Actions

  • Where testing is carried out as part of the crew change risk mitigation process, all test results should be known before sailing.

  • Changes to a previously approved COVID-19 crew change risk assessment must be subject to a formal management of change (MoC) process, approved by senior management.

  • Due consideration should be given to the ability to provide adequate medical care for someone onboard whose condition may deteriorate rapidly.

  • Uncertainty about the medical fitness of anyone scheduled to sail on the vessel, should be resolved before sailing.

Members may wish to refer to:

Latest Safety Flashes:

Diver injured foot during high pressure water jetting

A diver suffered a foot injury whilst working with high pressure water jetting (HPWJ) equipment.

Read more
High Voltage isolation near miss

There was a high voltage isolation near miss when crew were working on a TMS (Tether Management System).

Read more
BSEE: poorly maintained crane components cause multiple injuries during personnel transfers

BSEE has published Safety Alert 517 relating to poorly maintained crane components.

Read more
Unsafe attempt to transfer between vessels with no gangway

A crew member was observed attempting to transfer between two vessels alongside each other without using an approved gangway or designated means of access.

Read more
Chemical burn injury during maintenance

A crew member sustained second-degree chemical burns while cleaning fuel oil strainers.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.