We have recently learned of a crane whip line, on an offshore crane, parting when lifting a concrete mat weighing 4.5 tonnes from the vessel deck. 

What happened?

The load being lifted was well within the safe working load of the wire and the crane. Fortunately no-one was injured and no damage was sustained.

Our Member’s investigation revealed the following:

After investigation it was concluded that the wire rope parted due to internal corrosion which had been generated from lack on internal lubrication of the first, approximately, 22m of the wire from the hook end. This allowed corrosion of the internal strands generating a fatigue failure of the internal wire and a tensile failure of the external wire which resulted in a contribution of fatigue and loss of metallic areas. This conclusion was further substantiated when the wire was visually inspected at the contractor’s premises, where it was found that the first 16m was heavily corroded with its condition gradually improving to the 22m mark.

There had been inspection, greasing and destruct tests of the wire rope during its service. A 100% NDT inspection and high pressure lubrication of the wire had been undertaken a couple of months prior to the incident. It was subsequently found that, although the wire should have had a 100% inspection, NDT and high pressure lubrication, this was not achieved. When the wire rope was reeled off the crane onto a reel sited on the quayside and the NDT and pressure lubricating equipment positioned on the crane jib approximately 25m of the wire was omitted from the inspection. This was the section of wire that failed.

Our Member took the following actions:

The company involved has contacted the inspection company to verify that it has changed its quality procedures to include a method statement to ensure 100% NDT inspection and high-pressure lubrication.

The planned maintenance for the inspection of vessel crane wires is to be reviewed to determine if the frequency and mechanism is sufficient to actively monitor the condition of crane wire ropes in use.

Latest Safety Flashes:

NTSB: Vessel crane contact with shore-side crane

The National Transportation Safety Board of the United States (NTSB) has published a report and an investigation.

Read more
Dropped pallet during forklift operation

A pallet containing a load weighing 500kg dropped off a flatbed truck in close proximity to a delivery driver.

Read more
Dropped object hazard: access hatch to the communication dome

During a routine scheduled safety inspection of the main mast, it was discovered that the access hatch to one of the communication domes had fallen off.

Read more
Lock out/Tag out and unauthorised electrical connections/disconnections
Read more
MAIB: Is your Lead-Acid battery safe?

The UK Marine Accident Investigation Branch has published Safety Digest 1/2025, consisting of lessons from recent Marine Accident Reports.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.