BSEE: potentially catastrophic crane and lifting incidents

  • Safety Flash
  • Published on 24 April 2018
  • Generated on 8 October 2026
  • IMCA SF 09/18
  • 3 minute read

The United States’ Bureau of Safety and Environmental Enforcement (BSEE) has published Safety Alert no. 329 relating to four recent safety incidents involving cranes and lifting devices.

What happened?

  • While picking up a ‘slick joint’ to connect to a blowout preventer (BOP) stack, the joint, weighing over 19 tonnes, became dislodged and fell across the derrick, causing structural damage. No personnel were in the drop zone at the time of the incident.
  • During the lifting of a diesel tote tank from a supply vessel, when the tank was around 1.5m off the deck, the fast line parted and about 40m of cable, crane headache ball, and tote tank fell to the deck. Failure of the crane was caused by a frozen boom tip sheave, which caused the running line to jump the sheave. No personnel were in the drop zone at the time of the incident.
  • A crane boom fell freely, hitting the side of a jack-up rig and puncturing a hole in a diesel tank. The cause of the failure was missing retaining rings that held the pawl pin in place, causing the pin to dislodge. 38 barrels of diesel fuel escaped into the environment as a result of this incident.
  • During lifting of tubing from a rig to a workboat, one tubing joint slid out of a bundle of 12 joints and fell around 40m to the deck of the workboat below. The joint landed on an empty cutting box, puncturing the lid and then fell to the deck of the boat. No personnel on the boat were near the area of the cutting box and there were no injuries.

What actions were taken? What lessons were learned?

The BSEE recommends the following:

  • Ensure that proper planning is conducted prior to lifts. This planning should include a review of drop zones, identification of safe zones while the lift(s) occur(s) and verification that all participants are trained in the work practices to conduct lifts and/or perform inspections.
  • Review the mechanical integrity program to verify that crane maintenance and inspections are being performed according to company, crane manufacturer and regulatory requirements. Special consideration should be given to:
    • accessibility and inspection of a crane’s boom hoist lock pawl cylinder assembly
    • outer diameter measurements of boom, main, auxiliary and pendant cables
    • documentation on the installation date, manufacture date and identification information for boom, main, auxiliary and pendant cables
    • inspection and lubrication of sheaves
    • ensuring that wire rope size and sheave sizes are compatible
  • Verify that loads are centred, balanced and secured prior to initiating lifts.

The BSEE Safety Alert No. 329 can be found on the BSEE website.

You can also search through our published safety alerts by typing key words, such as lifting operations and dropped objects, into the ‘search safety flashes’ bar on the IMCA safety flash web page:

Members may wish to refer to the following guidance:

Latest Safety Flashes:

Hydraulic oil leak detected below moonpool

A hydraulic oil leak was identified below the moonpool after the worktable doors were opened.

Read more
Dropped scaffold board (kickplate) – SIF near miss

A scaffolding kickboard was accidentally dropped falling from a height of 6.5 metres to the main deck.

Read more
H₂S detected on deck

During vessel transit back to port, Hydrogen Sulphide (H₂S) was detected in the open space on the main deck.

Read more
Restoration and verification after maintenance

A missing flooring panel was identified beneath a 415V bow thruster electrical motor cabinet.

Read more
Vessel contact during materiel transfer in adverse weather

One vessel lost heading and position control because of the strong winds and swell, pushing it toward another.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.