Person injured when unsecured grating gave away

  • Safety Flash
  • Published on 16 May 2025
  • Generated on 7 April 2026
  • IMCA SF 09/25
  • 2 minute read

A worker sustained discomfort to the right shoulder and abrasions to the left leg when the grating they stepped on gave way.

What happened?

A worker sustained discomfort to the right shoulder and abrasions to the left leg when the grating they stepped on gave way, causing them to slip into grillage space, whilst holding onto lashings used as sea-fastenings. The incident occurred when the worker was positioned on the Multiple Reel Drive System (MRDS) steel rails while securing sea-fastening lashings. While holding a lashing, they stepped over a rail onto an external grating panel. The grating panel gave way, causing the individual to slip between the grating panels into the grillage space to deck (<1m) below. 

What went wrong?

·       As part of mobilisation activities, a third-party hot work subcontractor had been engaged to cut and weld sections of grating panel to provide a safe walkway around the Multiple Reel Drive System.

·       Before finishing the task, the hot work subcontractor was redirected to complete another task deemed of higher priority at the time.

·       The area was not made safe with barricading – this would have signalled that the grating installation had not been fully completed before the hot works subcontractor moved to the different task.

·       The grating panel installation was not completed before the injured person accessed the walkway, which the injured person assumed was safe to walk on.

Lessons

·       If you have to leave a task unfinished to do something else.

̶            Assess the risk to other people of leaving the task unfinished.

̶            Ensure the unfinished state of the task is communicated to your supervisor and your colleagues so that they are fully aware.

̶            Install barricades as a visual signal if the work area should not be accessed.

·       Ensure that the worksite is made safe for other users.

·       Check the worksite is checked before starting work.

Latest Safety Flashes:

MAIB: Sinking of tug Biter with loss of two lives

MAIB has published Accident Investigation 17/2024 relating to the girting and capsize of tug Biter with the loss of two lives.

Read more
Dropped object – strop parted over sharp edge

A cylinder was lifted to a height of approximately 6 metres over deck of the vessel, the sharp steel edges of the cylinder cut through the firehose protection and caused the strop to part.

Read more
Person injured when pry bar slipped

A crew member who was applying downward pressure to their pry bar to lift a track, fell towards the deck when the pry bar slipped.

Read more
MSF: High potential near miss during FRC maintenance

The Marine Safety Forum has published Safety Alert 26-01 relating to an incident where there was an unplanned lowering of an FRC to the sea

Read more
BSEE: Crane incident leads to serious facial injuries

BSEE has published Safety Alert 512 relating to a crane incident during well abandonment which led to a worker being struck and suffering serious facial injuries.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.