Near miss: Floor Plate fell from Main Mast during storm

  • Safety Flash
  • Published on 4 May 2022
  • Generated on 6 November 2026
  • IMCA SF 11/22
  • 2 minute read

A floor plate fell from the main mast to the deck during a storm.

What happened?

At the time there were violent storm force winds of 55 to 60 knots with an 11m swell. A crew member suddenly heard an object falling from above.  It landed near the upper deck port forward crane. It was a piece of 50 x 80 cm aluminium plate with 4 holes for securing, weighing about 2Kg. There were no injuries nor property damage.

Photo of floor plate
Photo of missing floor plate

What went wrong?

The four screws securing the floor plate had sheared. The plate was from the mid platform of the mast at the base the Inmarsat dome mast.

The screws had been replaced by a sub-contractor during fabric repairs, just over one year previously, and were found to be too short, and of too poor a quality, to ensure the plate remained secured adequately.

Actions

  • Re-secured the plate with proper fixings.
  • Held a thorough check of all similar plates on deck, especially in areas where this particular sub-contractor had been working, so as to avoid similar potential problem.
  • Fed back to the sub-contractor about this near miss, requiring higher attention to quality performance in future work.

Latest Safety Flashes:

Cyber-attack on vessel

An oil tanker suffered a cybersecurity incident.

Read more
MAIB: Normalising of unsafe practice – fatal man overboard incident

MAIB have published Accident Investigation Report 16/2026 into a fatal man overboard incident on board a bulk carrier offshore Sweden.

Read more
Dust explosion in Bow thruster motor

Upon activation of the bow thruster, there was a loud explosion within the forward section of the workboat.

Read more
Dropped bulk bag during loading operations

A dropped object incident occurred during quayside lifting when a bulk bag failed due to incorrect loading.

Read more
Failure of sea-fastening on the leg of a jack-up barge

During a sea passage, prevailing sea conditions caused a jack-up barge to experience rolling and pitching motions.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.