Near-miss: Dropped object
- Safety Flash
- Published on 14 November 2012
- Generated on 23 November 2026
- IMCA SF 12/12
- 2 minute read
Jump to:
A Member has reported an incident in which a pipe-wrench weighing 1.2kg fell 15m to the deck.
What happened?
The incident occurred when hand tools were being hoisted up for use by personnel working at height. Two workers at height were preparing to lift three tools at once from the deck to their working platform, using a low pressure air hoist. A tag line was attached to one of the tools to help guide and avoid entanglement. Once the load could no longer be controlled by the tag line a ‘no go zone’ was put in place and the DROPS zone directly below was cleared of personnel. As the tools came to the level of the working platform one of them got caught on the bottom of the platform, which tore the stitching of the single leg tether (rated at 30lbs breaking strain). The result was that the tool fell 15m back to the deck. There were no injuries. The workplace was made safe and a safety stand-down was held.
Our Member’s investigation noted the following:
- The crew had held a job safety analysis (JSA) meeting beforehand and identified and assembled the tools required for the job.
- The immediate cause of the incident was that the tool became caught during the lift, which caused the DROPS tether stitching to tear, allowing the pipe wrench to fall to the deck below.
Our Member drew the following lessons:
- DROPS training plans should be continually emphasized.
- Care should be taken with the safe work load (SWL) of straps and tethers used for hoisting tools.
- Single leg tethers should not be used as lifting devices.
- Establish a pre-use inspection and regular inspection cycle for DROPS equipment.
- Carefully identify entanglement points on the lift route when hoisting tools aloft.
Members’ attention is drawn to the following IMCA material which may be of assistance:
- Guidelines for lifting operations
- Lifting equipment (pocket card)
- Working at height (pocket card)
- Avoiding dropped objects (poster)
- Avoiding dropped objects (pocket card)
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.